Keyboard shortcuts

Press ← or → to navigate between chapters

Press S or / to search in the book

Press ? to show this help

Press Esc to hide this help

Glossary

AppFS — The badge.team application filesystem adopted from the Tanmatsu: an app is a standard, unmodified ESP-IDF binary with slug/title/version metadata in a dedicated partition. See ESP32.

BMC / IPMI — Baseboard management controller / Intelligent Platform Management Interface: the enterprise remote management (KVM, power, sensors) built into the core machines. Versions and settings are still to be audited (epic #1081).

Ceph — A distributed storage system avoided where possible in this estate (Drew, settled 2026-11-23); LINSTOR-first is the direction.

Cozystack — The Kubernetes platform planned for the cluster: it decides storage, tenancy and GitOps, and provides LINSTOR storage, CNPG Postgres and SeaweedFS buckets. Planned, not installed.

CNPG — CloudNativePG, the managed Postgres operator the programme uses via Cozystack. The research brief’s decision: use Cozystack’s CNPG-based Postgres; do not deploy a second operator. Runs as a primary with streaming replicas; see Storage: LINSTOR and DRBD.

DRBD — Distributed Replicated Block Device: block-level replication between machines, managed by LINSTOR in the cluster design. Drew’s sketch replicates across three machines so data loss needs the same failure on two at once.

DX010 — Celestica DX010: the 100GbE fabric switch of the research inventory (32× QSFP28, SONiC). The dictated “DXO10” and the issue-title spelling “Celestia DX010” are the same device.

Falco — A runtime-detection tool (eBPF/syscall behaviour watching); the design’s tripwire layer — detection, not prevention. Not deployed. See Security: Falco runtime detection.

LINSTOR — The storage management layer in Cozystack that provisions DRBD-replicated volumes on ZFS. Design only in this programme.

P9 — The fleet-drafted lab-integration design (doc/living/lab-integration.md). A draft awaiting Drew’s ratification (#8873); nothing in it is decided.

RAID 100 — The register’s name for the mid NVMe tier’s layout: stripe 3 × mirror 2 (6 drives), so two drives must die to down a machine.

RustFS — An S3-compatible object store, one of the two candidates for CNPG backups and buckets on the HDD pools. The RustFS-versus-SeaweedFS verdict landed 2026-11-24: SeaweedFS stays as Cozystack’s S3 layer, and RustFS is pilot-only for standalone large-object workloads outside Cozystack, re-evaluated after a year of GA exposure. See Object storage: RustFS and SeaweedFS.

TALM — cozystack/talm: the tool that templates and applies Talos machine configuration per node from files in git. Its per-node disk flow (#1812) is the book’s one proven cluster piece.

Talos — Talos Linux, the cluster’s operating system: installed declaratively via TALM, never hand-built. No node is installed yet.

Tanmatsu — The handheld terminal (Nicolai Electronics / badge.team lineage) built on an ESP32-P4 plus ESP32-C6, named as the reference design for worlds-as-apps on the embedded tier. The dictated “tenmazu” is this device.